AA-6200 Atomic Absorption Spectrophotometer
Quality Performance at an Affordable Price
Shimadzu's double beam AA-6200 atomic absorption spectrophotometer combines high performance with affordability. The double beam system provides the superior baseline stability expected from high-performance optical systems at an affordable price. Windows®-based software Wizard functions provides easy operation for system control and data processing. A compact system, the AA-6200 uses some of the smallest bench space of any atomic absorption spectrophotometer in the world. In spite of its compactness, the performance and capability is superior. In fact, the AA-6200 outperforms other atomic absorption instruments many times its physical size.
Specifications
| Optics | Double Beam (chopper mirror) | |
|---|---|---|
| Monochromator | aberration corrected Czerny-Turner monochromator Holographic grating (1,600 lines/mm) |
|
| Wavelength range | 190-900 nm Automated wavelength selection |
|
| Slit | 0.2nm, 0.7 nm Manual setting | |
| Background Correction | D2-Lamp method | |
| Lamp Turret | 2-lamps simultaneously lit (manual turret) | |
| Lamp Mode | Emission, Non-BGC, BGC-D2 | |
| Frequency | 100Hz | |
| Nebulizer | Nebulizer integrated impact bead and jacket tip Pt/Ir capillary |
|
| Chamber | Polypropylene | |
| Burner | Fixed back/forward position and burner height (Simply switching of Air/C2H2 and N2O/ C2H2 burner) Titanium 10cm slot burner (Optional high temperature burner) |
|
| Gas Control | Manual setting of flow rate Automatic Air/ N2O switching system |
|
| Safety | Gas pressure monitoring to prevent flashback Automatic flame monitoring Safety interlock for misuse of burner Automatic flame extinguish when power failure |
|
| Ignition | Push ignite button | |
| Software | Software based on MS-WindowsTM | |
| Dimension and weight | W690 x D425 x H370 mm, 38 kg | |
| Power requirements | AC220V, 230V, 50/60Hz, 300 VA (Requires transformer for AC115V) (Certification of CE marking) |
|
| Ambient temperature and humidity range | Temperature: 10~35°C Humidity: 45~80% (but less than 70% if temperature is over 30°C |
|
| Standard accessories | Burner Head of 10cm slot. Nebulizer assembly. Deuterium lamp. Drain tube PTFE tube for sample suction. Hose assembly for Air. Hose assembly for C2H2. Hose band RS-232C connection cable (9P-9P). AC cable for 220, 230V | |
Personal Computer requirements
|
|
| Operating environment: MS-Windows |
| CPU: Pentium II 200MHz or better) |
| RAM: More than 128MB |
| CRT: SVGA (800x600) or Higher |
| Hard disk: More than 200MB required to install the AA software |