UV-3600

UV-VIS Spectrophotometers

UV-3600

The UV-3600 UV-VIS-NIR Spectrophotometer is a new additional model in our product lineup of high-end UV-VIS-NIR spectrophotometers.
The UV-3600, a successor model to the UV-3150/3101, is a unique UV-VIS-NIR instrument that provides for optimum sensitivity from 185-3,300nm.

Features

High Sensitivity - The Only 3 Detector System
Equipped with 3 detectors: A PMT detector (photomultiplier tube) for the ultraviolet and visible regions, and InGaAs and PbS detectors for near infrared region. The InGaAs detector bridges the gap between the PMT - PbS switching wavelength where sensitivity is typically low to ensure high sensitivity over the entire measurement wavelength range. With <0.00003 Abs noise at 1500 nm, the world´s lowest noise level is achieved.

The following figures represents relationships between detectors and measurable ranges

High Resolution - Wide Measurement Range & Ultra-low Stray Light
With its high performance double monochromator, ultra-low stray light (0.00005% or less at 340 nm) is achieved at high resolution (highest resolution 0.1 nm). With a measurement wavelength range of 185 - 3300 nm, measurement is possible over a wide range including the ultraviolet, visible and near infrared regions. This allows spectroscopic analysis in a wide variety of fields.

Software

All-in-one Software
UVProbe software for the UV-3600 includes functions for spectrum measurement, quantitation, kinetics and a report generator. Multiple security and audit-trail functions ensure the reliability of data.

Specifications

Wavelength range 185nm - 3300nm
Spectral Bandwidth8 steps in ultraviolet/visible region 0.1, 0.2, 0.5, 1, 2, 3, 5, 8 nm
10 steps in near-infrared region 0.2, 0.5, 1, 2, 3, 5, 8, 12, 20, 32 nm
Resolution 0.1 nm
Sampling Pitch0.01 - 5 nm
Wavelength accuracy UV/VIS region: ±0.2 nm NIR region: ±0. 8 nm
Wavelength repeatability UV/VIS region: less than ±0.08 nm NIR region: less than ±0.32 nm
Stray light < 0.00008% (220 nm, NaI)
< 0.00005% (340 nm, NaNO2)
< 0.0005% (1420 nm, H2O)
< 0.005% (2365 nm, CHCl3)
Photometric range -6 to 6 Abs
Noise0.00005 Abs or less (500 nm), 0.00008 Abs or less (900 nm), 0.00003 Abs or less (1500 nm)
Slit width 2nm, RMS value at 1 sec. response
Photometric System Double beam
Dimensions1020(W) x 660(D) x 275(H) mm

Accessories

Abundant Accessories for a Wide Variety of Applications

The multipurpose large-sample compartment and integrating sphere attachment enable measurement of solid samples, and with the guaranteed precision of the ASR Series (Absolute Specular Reflectance) attachments, high accuracy, absolute reflectance measurements are possible. Various cell holders like the constant-temperature cell holder and ultra-micro cell holder can also be mounted to enable a wide range of measurement possibilities.