90° Peeling Test for Adhesive Tapes [Standard No. ISO 29862:2007 (JIS Z 0237:2009)]

As the chemical industry has developed, adhesives using synthetic polymers as raw materials have been commercialized. These adhesives are often used in a variety of industrial fields, including electronics and electrical machinery. This article introduces an example of a 90° peeling test for adhesives used in adhesive tapes.

 

Measurements and Jigs

The sample was an ordinary adhesive tape cut to a width of 24 mm and a length of 300 mm; it was set on a SUS304 stainless steel plate. An adhesive tape peeling test attachment, which is capable of peeling off tape at an angle of 90° from the plate on which the sample was set, was used as the test jig.

 

Measurements Results

Peeling Test

Fig. 1: Peeling Test

Relationship between the Test Force and Stroke

Fig. 2: Relationship between the Test Force and Stroke

The test was implemented at a loading speed of 300 mm/min. After measurement started, measurement values for the initial length of 25 mm were discarded. Afterwards, the adhesive force measurement values for a length of 50 mm peeled off the plate were averaged. This average value was taken as the peeling adhesive force.

 

Table 1: Result

Peeling Adhesive Force
0.238 N/10 mm
 

Tensile Testing System for Plastic Materials

Tester AGS-X
Load Cell 50 N
Testing Jig Adhesive Tape Peeling Test Attachment
Software TRAPEZIUM LITE

Trapezium lite software and ags-x table-top precision universal tester

  • A high-precision load cell is adopted. (The high-precision type is class 0.5; the standard-precision type is class 1.)
    Accuracy is guaranteed over a wide range, from 1/500 to 1/1 of the load cell capacity. This supports highly reliable test evaluations.
  • Crosshead speed range
    Tests can be performed over a wide range from 0.001 mm/min to 1,000 mm/min.
  • High-speed sampling
    High-speed sampling, as fast as 1 msec.
  • TRAPEZIUMX LITE X operational software
    This is simple, highly effective software.
  • Jog controller (optional)
    This allows hand-held control of the crosshead position. Fine position adjustment is possible using the jog dial.
  • Optional Test Devices
    A variety of tests can be conducted by switching between an abundance of jigs in the lineup.
 

Industries

For Research Use Only. Not for use in diagnostic procedures.

Top of This Page