TOC-1000e Options & Consumables

On-Line TOC Analyzer for Pure Water

Options

Description P/N Remarks
Vial Sampler 638-57230-41 Four 40-mL vials
Bracket Kit 638-23033-41 Enables mounting to either a wall or pole.
External I/O Kit 638-79217-41 Enables analog output and contact input/output.
Power Supply
Terminal Block Kit
638-68186-41 Used when the power cord is connected directly to the instrument.
Sample Filter 040-22305-45 60-µm element for 1/8-inch OD tubing
Needle Valve for Adjusting Sample Flowrate 040-22308-03 For adjusting sample flowrate in 1/8-inch OD tubing
Sample Flow Shutoff Valve 040-07042-01 Used to cut off flow of water to the instrument during maintenance.
Reducer Union 035-60414-50 Tubing OD adapter from 1/8 to 1/4-inch
Printer 220-95367-02 Epson TM-T88VI Series printer for TOC-1000e
Printer Wall Mount 220-95367-03 Wall mount bracket set for Epson TM-T88VI TOC-1000e printer
Calibrated Thermometer 638-65601-41 Calibration Thermometer for on-site validation of eTOC series instruments.

Routine Consumable Parts

 
Description P/N Remarks
Excimer Lamp 638-69201-41 Unlike low-pressure mercury lamps, which have been widely used in conventional models, the excimer lamp does not contain mercury, which reduces the environmental burden upon disposal. Recommended to replace once every year.
Pump Head 638-59384-41 Hands-free replacement pump head for controlling sample flow during measurement.
Sample Filter Element 040-22305-80 Replacement element for sample filter
Printer Paper 220-95367-04 50 rolls, 8 cm x 70.1 m each

Certified Standard Solutions

Application P/N Remarks
Blank Water 638-60252-91 Four vials of blank water for thermometer validation and rinsing
Set of 147 µS/cm Potassium Chloride Standard Conductivity Solutions 638-60254-91 Two vials of 147 µS/cm KCl and one vial of blank water for conductivity calibration
Set of 0-250-500 µg/L Sucrose Standard
TOC Solutions
638-60255-91 One vial of blank water and one vial each of 250 and 500 µg/L sucrose for TOC calibration and validation
Set of 0-500 µg/L Sucrose Standard TOC Solutions 638-60256-91 One vial of blank water and one vial of 500 µg/L sucrose for TOC calibration
Set of 0-500-1000-2000 µg/L Sucrose Standard TOC Solutions 638-60257-91 One vial of blank water and one vial each of 500, 1000, and 2000 µg/L sucrose for TOC calibration and validation
Set of 0-2000 µg/L Sucrose Standard TOC Solutions 638-60258-91 One vial of blank water and one vial of 2000 µg/L sucrose for TOC calibration
USP 643 System Suitability Test Set, Confirmed (USP Standard) 638-60259-91 One vial of blank water, one vial of 500 µg/L sucrose, and one vial of 500 µg/L 1,4-benzoquinone for TOC system suitability test
USP 643 System Suitability Test Set, Equivalent 638-60260-91 One vial of blank water, one vial of 500 µg/L sucrose, and one vial of 500 µg/L 1,4-benzoquinone for TOC system suitability test
 

For Research Use Only. Not for use in diagnostic procedures.

Top of This Page