Nexera-e Comprehensive Two-Dimensional Liquid Chromatograph

Comprehensive Chromatography

Maximizing the full potential of two-orthogonal separation systems to perform comprehensive two-dimensional separation

Comprehensive 2D-LC is a new analytical methodology combining two independent separation modes orthogonally, greatly increasing separation efficiency. The combination of different modes enables the separation of peaks that are difficult to separate using conventional LC, providing excellent results for the analysis of complex sample matrices.

Unlike other conventional two-dimensional techniques the Nexera-e provides complete separation as a result of the combination of orthogonal 1st and 2nd dimensions. Comprehensive 2D-LC fully utilizes both separation systems to achieve the ultimate separation power.

mono-dimensional separation to 1st and 2nd dimensional separation

Insufficient peak separation may be observed for complicated samples.

The peaks separated by the 1st-dimensional system will be isolated by the 2nd-dimensional system.

 

Differences between a conventional 1D-LC and a comprehensive 2D-LC

 

Comprehensive 2D-LC fractionates the 1st-dimensional eluent and successively separates the fraction on-line with the 2nd-dimensional system. Therefore, the 1st-dimensional system intersects with the 2nd-dimensional system at the dual valves and dual-loops. With valve switching, these loops continue the fractionation of the eluent from the 1st-dimensional system and the injection of the fraction to the 2nd-dimensional system alternately.

flow line and mechanism of the comprehensive 2d-lc system

Flow line and mechanism of the comprehensive 2D-LC system

Analysis of samples on a two-dimensional map

On a two-dimensional map, since each 1st-dimensional axis and 2nd-dimensional axis are set according to different separation conditions, the physical properties of compounds and their position on a map correlate.

By grouping a compound with a similar structure, it is possible to match each compound group visually or to analyze the physical properties of an unknown compound.

postivie and negative mode of LC/MS

Simultaneous Determination of 39 Phospholipid Componds
(PG: phosphatidylglycerol, PE: phosphatidyl ethanolamine, PA: phosphatidic acid,
PI: phosphatidylinositol, PS: phosphatidylserine, PC: phosphatidylcholine)

Each phosphatide compound is separated based on its polar group (class) in a normal 1st-dimensional phase separation. And it is separated according to the chain length of fatty acids by a 2nd-dimensional reverse phase analysis. Each compound is grouped for each class and showed in the above figures. Although some components are strongly detected in the positive mode and others in the negative mode, it is possible to acquire both data in one analysis utilizing the Ultra-Fast Polarity Switching [UFswitching] of the LCMS-8050 LC/MS/MS.

* Appearance and specifications are subject to change without notice.

For Research Use Only. Not for use in diagnostic procedures.

Top of This Page