UV-Vis Water Analysis System - Specs
UV-1280 Spectrophotometer
Measurement
Combining the UV-1280 and a simple reagent kit from Kyoritsu Chemical-Check Lab ensures easy operation, and accurate, stable water analysis.
| Item name | Reagent type / cell Other necessary instruments |
Measurement principle Measurement range(mg/L) / measurement time |
|
|---|---|---|---|
| ClO | Residual Chlorine(Free) |
|
DPD Absorptiometry
|
| CN | Free Cyanide |
|
4-Pyridinecarboxylic Acid Absorptiometry
|
| CNT | Total Cyanide |
|
Distillation and Picric Acid Absorptiometry
|
| COD | COD |
|
Oxidation by potassium permanganate in alkaline medium Method
|
| Color | Chromaticity |
|
Verification by Platinum Cobalt Color standard solution
|
| Cr6+ | Hexavalent Chromium |
|
Diphenylcarbazide Absorptiometry
|
| Cr6+-50 | Hexavalent Chromium-50mm cell |
|
Diphenylcarbazide Absorptiometry
|
| Cr6+(D) | Hexavalent Chromium (Low Range) |
|
Diphenylcarbazide Absorptiometry Coupled with Collecting on Membrane Filter
|
| Cr6+(WAK) | Hexavalent Chromium (PACKTEST) |
|
Diphenylcarbazide Absorptiometry
|
| CrT | Total Chromium |
|
Oxidation and Diphenylcarbazide Absorptiometry
|
| Cu | Copper |
|
Bathocuproine Absorptiometry
|
| F | Fluorine (Free) |
|
Lanthanum - Alizarin Complexon Absorptiometry
|
| Fe | Iron |
|
Reduction and o-Phenanthroline Absorptiometry
|
| Fe (D) | Iron (Low Range) |
|
Reduction and Bathophenanthroline Absorptiometry
|
| FOR | Formaldehyde |
|
MBTH Absorptiometry
|
| H2O2 | Hydrogen Peroxide |
|
4-Aminoantipyline Absorptiometry with Enzyme
|
| Mn | Manganese |
|
Potassium Periodate Absorptiometry
|
| NH4 | Ammonium |
|
Indophenol Blue Absorptiometry
|
| NH4-N | Ammonium Nitrogen |
|
Indophenol Blue Absorptiometry
|
| Ni | Nickel |
|
Nioxime Absorptiometry
|
| NO2 | Nitrite |
|
Naphthylethylenediamine Absorptiometry
|
| NO2-N | Nitrite Nitrogen |
|
Naphthylethylenediamine Absorptiometry
|
| NO3 (1) | Nitrate (No Nitrite) |
|
Reduction and Naphthylethylenediamine Absorptiometry
|
| NO3 (2) | Nitrate (Nitrite 0.015mg / L or less) |
|
Reduction and Naphthylethylenediamine Absorptiometry
|
| NO3 (3) | Nitrate (Nitrite 5mg / L or less) |
|
Reduction and Naphthylethylenediamine Absorptiometry
|
| NO3-N (1) | Nitrate Nitrogen (No Nitrite Nitrogen) |
|
Reduction and Naphthylethylenediamine Absorptiometry
|
| NO3-N (2) | Nitrate Nitrogen (Nitrite Nitrogen 0.015mg / L or less) |
|
Reduction and Naphthylethylenediamine Absorptiometry
|
| NO3-N (3) | Nitrate Nitrogen (Nitrite Nitrogen 1.5mg / L or less) |
|
Reduction and Naphthylethylenediamine Absorptiometry
|
| Pb | Lead |
|
MetaSEP Analig® and PAR Absorptiometry
|
| Phenol | Phenol |
|
4-Aminoantipyline Absorptiometry with Enzyme
|
| PO4 | Phosphate |
|
Molybdenum Blue Absorptiometry
|
| PO4(D) | Phosphate (Enzymatic method) |
|
4-Aminoantipyline Absorptiometry with Enzyme
|
| PO4-P | Phosphate Phosphorus |
|
Molybdenum Blue Absorptiometry
|
| PO4-P(D) | Phosphate Phosphorus (Enzymatic method) |
|
4-Aminoantipyline Absorptiometry with Enzyme
|
| S | Sulfide (Hydrogen Sulfide) |
|
Methylene Blue Absorptiometry
|
| TH | Total Hardness |
|
Phthalein Complexone Absorptiometry
|
| Turbid (FTU) | Turbidity(Formazin) |
|
Verification by Formazin standard solution
|
| Turbid (PS) | Turbidity(Polystyrene) |
|
Verification by Polystyrene standard solution
|
| Zn (D) | Zinc(Low Range) |
|
5-Br-PAPS Absorptiometry
|
*1 One dedicated cup is included in the reagent kit.
*2 Please use the dedicated cup (WAK-CC 10 Pack Test Cup, 10 pieces) manufactured by Kyoritsu Chemical Research Institute.
*3 Approximate total time including pre-processing.

* If the program version of your UV-1280 is 1.xx, your program must be updated by a Shimadzu service engineer.
The program version is displayed on the bottom right of the Initialization screen.