i-Series Plus Integrated HPLC Systems

i-Series Plus

Providing the Ultimate Balance of High-Level Performance and Ease-of-Use in an Integrated HPLC

You asked for it, you got it.

Every i-Series has a touch-screen LCD display for easy, intuitive system control and chromatogram viewing, built-in degassing, quaternary solvent delivery, autosampler and UV or PDA detector. As always, sample injections are the fastest around (< 14 seconds), with ultra-low carryover.

Specifications

Hardware Specifications

Pump

 
Prominence-i
Nexera-i
Degassing Unit
Five Lines: Mobile phase 4 + Rinse solution 1 (Volume 400 μL)
Pulsation
0.1 MPa (1.0 mL/min,10 MPa, Water)
Flow rate range
0.0001 to 10 mL/min
Flow rate precision
< 0.06 %RSD or < 0.02 minSD, below whichever is greater
Elution Mode
Four-solvent low-pressure gradient
Gradient / range
0 to 100%, in 0.1% steps
Gradient / concentration precision
±0.1% (1 mL/min,10 MPa, Specified condition)

Maximum pressure
44 MPa (0.0001 to 5 mL/min)
22 MPa (5.0001 to 10 mL/min)
66 MPa (0.0001 to 3 mL/min)
44 MPa (3.0001 to 5 mL/min)
22 MPa (5.0001 to 10 mL/min)

Autosampler

  Prominence-i Nexera-i
Injection method Needle-in-flowpath
Injection volume accuracy ±% (50 μL, N = 10)
Injection volume range 0.1 to 100 μL
(Option: 0.1 to 50 μL, 1 to 500 μL, 1 to 2,000 μL)
0.1 to 50 μL
(Option: 0.1 to 100 μL, 1 to 500 μL, 1 to 2,000 μL)
Injection volume reproducibility RSD < 0.20% (5.0?2000 μL), RSD < 0.25% (2.0?4.9 μL)
RSD < 0.5% (1.0?1.9 μL), RSD < 1.0% (0.5?0.9 μL)
Injection cycle time Minimum 14 seconds (Specified condition)
Samples capacity 336 (1 mL), 216 (1.5 mL), 112 (4 mL), 4 (MTP/DWP)
Sample cooler 4 to 45°C (Room temperature needs to be 30°C or lower and the humidity 70% or less to go down to 4°C. Room temperature needs to be 15°C or higher to go up to 45°C.)
*No sampler cooler included in LC-2030 model
Injection linearity > 0.9999 (1 to 100 μL, Specified condition) > 0.9999 (1 to 50 μL, Standard Sample Loop, Specified condition)
> 0.9999 (1 to 100 μL, 100 μL Sample Loop (Option), Specified condition)

Oven

 
Prominence-i
Nexera-i
Oven Capacity
6 columns at 10 cm max., 3 pieces at 10 cm to 30 cm
Title
Room temperature ± 12 to 90°C, Setting range 4 to 90°C

UV Detector

 
Prominence-i
Nexera-i
Wavelength Range
190 to 700 nm
Noise level
±2.5 × 10-6 AU, (250 nm, Specified condition)
Flow cell
12 μL (10 mm, TC), 12 MPa 8 μL (10 mm, TC), 12 MPa
Option cell
High-Speed: 8 μL (10 mm, TC)
Semi-micro: 2.5 μL (5mm, TC)
Conventional: 12 μL (10 mm, TC)
Semi-micro: 2.5 μL (5 mm, TC)

PDA Detector

  Prominence-i
Nexera-i
Wavelength Range
190 to 800 nm
Noise level
±3 × 10-6 AU, (250 nm, Specified condition)
Flow cell
10 μL (10 mm, TC), 12 MPa
8 μL (10 mm, TC), 12 MPa
Option cell
High-Speed: 8 μL (10 mm, TC)
Semi-micro: 2.5 μL (5mm, TC)
Conventional: 12 μL (10 mm, TC)
Semi-micro: 2.5 μL (5 mm, TC)

For Research Use Only. Not for use in diagnostic procedures.