LC-2030C NT HPLC System

Guaranteed Data Quality With No Experience Needed

Pump

Degassing unit Five Lines: Mobile phase 4 + Rinse solution 1 (Volume 400 µL)
Pumping method Parallel-type double plunger
Pulsation ≤ 0.1 MPa (1.0 mL/min,10 MPa, Water)
Flow rate setting range 0.0001 to 10 mL/min
Flow rate accuracy ≤ ±1% or ±2 µL/min, below whichever is greater (0.01 to 2 mL/min, Specified conditions)
≤ ±2% (2 to 5 mL/min, Specified conditions)
Flow rate precision ≤ 0.06 %RSD or ≤ 0.02 minSD, below whichever is greater
Configuration Four-solvent low-pressure gradient
Gradient / range of set concentrations 0 to 100%, in 0.1% steps
Gradient / concentration accuracy ±0.5% (0.1 to 2 mL/min, 1 to 20 MPa, Specified conditions)
Gradient / concentration precision ±0.1% (1 mL/min, 10 MPa, Specified conditions)
Maximum pressure Packed column side : 34 MPa (0.0001 to 5 mL/min) , 22 MPa (5.0001 to 10 mL/min)
Slide-in column side : 7 MPa (0.0001 to 0.3 mL/min)
System Delay Volume approximately 615 µL (Packed column side)
approximately 620 µL (Slide-in column side) (Option: none)

Autosampler

Injection method Total-volume sample injection
Injection volume accuracy ±1% (50 µL, N=10)
Injection volume setting range 0.1 to 100 µL (Option:0.1 to 50 µL)
Injection volume reproducibility RSD ≤0.20% (5.0 to 100 µL), RSD ≤0.25% (2.0 to 4.9 µL)
RSD ≤0.5% (1.0 to 1.9 µL), RSD ≤1.0% (0.5 to 0.9 µL)
Cross-contamination 0.0025% (Caffeine, Specified conditions)
Injection cycle time Min. 14 sec (Specified conditions)
Samples for processing 336 (1 mL), 216 (1.5 mL), 112 (4 mL), 4 (MTP/DWP)
Sample cooler 4 to 45°C
Injection linearity ≥0.9999 (1 to 100 µL, Specified conditions)

Column Oven

Heating and cooling method Forced air circulation method
Containable column size Slide-in column
Packed column (1 pieces at 10 to 25 cm)
Temperature control range Room temperature −5 to 60°C,
Setting range 4 to 60°C (To 50°C for slide-in column)
Temperature control precision ±0.1°C
Temperature stability ±0.8°C (Specified conditions)
Flow rate switching valve Not available

PDA Detector

Wavelength range 190 to 800 nm
Spectral resolution 1.4 nm (Specified condition)
Slit width 1.2 nm, 8 nm
Device resolution 0.6 nm/pixel
Number of photodiode array elements 1024
Wavelength accuracy ≤ ±1 nm
Noise level ≤ ±3 × 10−6 AU (250 nm, reference: 350 nm, Specified conditions)
Drift ≤ 500 × 10−6 AU/h (250 nm, reference: 350 nm, Specified conditions)
Linearity Up to 2 AU (5%)
Sampling rate Up to 100 Hz
Light source Deuterium (D2) lamp (Standard), tungsten (W) lamp (option)
Flow Cell 8 µL (10mm, TC), 12 MPa
Option cell Conventional: 10 µL (10 mm, TC),
Semi-micro: 2.5 µL (5 mm, TC)

Miscellaneous

Dimensions W410×H605×D500 mm
Weight 67 kg
Available pH range 1 to 13
Materials for parts in contact with liquids Stainless steel (SUS316L, SUS316), FEP, PEEK, PTFE, perfluoroelastomer, ruby,
sapphire, Hastelloy® C, GFP, ceramic, PFA, quartz, PPS
Workstation LabSolutions LC/GC Ver. 5.92 or later,
LabSolutions DB/CS Ver. 6.82 SP1 or later (Incompatible with LCsolution )

For Research Use Only. Not for use in diagnostic procedures.

Top of This Page